id mission quality status last modified validity start validity stop description
#57 S1B DEGRADED 2020-07-03 15:23:51 2020-06-22 19:27:28 2020-07-01 21:17:10 S-1B issue on the WV OCN: anomaly on swell spectrum energy with IPF 3.3x
#56 S1A DEGRADED 2020-07-03 15:21:45 2020-06-22 20:17:50 2020-07-02 02:00:46 S-1A issue on the WV OCN: anomaly on swell spectrum energy with IPF 3.3x
#55 S1A DEGRADED 2020-06-15 11:50:27 2020-03-08 17:35:11 2020-03-08 17:36:01 S-1A radiometric jumps on S1A IW products on 08/03/2020
#54 S1B DEGRADED 2020-03-13 14:53:16 2020-03-11 01:29:03 2020-03-12 01:46:50 S-1B OCN Products generated with missing wind information (OWI) content on 11th March 2020
#53 S1A DEGRADED 2020-03-13 14:44:49 2020-03-10 18:41:02 2020-03-11 23:49:57 S-1A OCN Products generated with missing wind information (OWI) content on 11th March 2020
#32 S1A DEGRADED 2018-04-06 08:27:19 2015-05-17 00:03:40 2015-05-18 23:14:45 S-1A mis synchronisation with impact on azimuth bandwidth synchronisation for InSAR applications